X3-IES-P

X3-IES-P

8kW / 10kW / 12kW / 15kW

Robust

  • Robust backup ability, switchover time <10ms(UPS level), up to 200% EPS output for 10s, support half-wave loads

  • Battery heating technology, -30°C extreme environment operation



Safe

  • IP66 protection level

  • AC&DC SPD type II, always guarding the inverter

  • AFCI optional




Intelligent

  • VPP ready, SolaX cloud support resource aggregator(IEEE 2030.5, OpenADR)

  • Micro-grid ready

  • Support intelligent loads management①(e.g., Heat pump, EV charger), combined with 7×24h TOU to achieve ecient peak shaving

  • Support Wireless meter solution



Economically

  • All in one design, plug and play, expandable and installation easily 3MPPT is capable of handling complex multi-faceted roof installations

  • Maximum 200% oversize,200% PV input power, 20A DC single string input current,

  • Low start output voltage makes inverter longer working time

  • Built-in shadow tracking function



Why X3-IES-P

Choose X3-IES-P for its robust backup capability, with a swift switchover time of less than 10ms (UPS-level) and an impressive 200% EPS output for 10 seconds, ensuring uninterrupted power supply. Its battery heating technology enables operation in extreme -30°C environments. Safety is paramount, with IP66 protection, AC&DC SPD Type II safeguarding the inverter, and optional AFCI for added protection. Intelligence highlights include VPP readiness, SolaX cloud integration, micro-grid compatibility, and smart load management, optimizing energy usage with 7x24h TOU for efficient peak shaving. Economically, the all-in-one design is plug-and-play, expandable, and easy to install, handling complex multi-faceted roof installations with 3MPPT and a 200% oversize capacity, maximizing PV input power and inverter working time.

X3-IES-8K-P
X3-IES-10K-P
X3-IES-12K-P
X3-IES-15K-P

X3-IES-8K-P
INPUT PV
Max. recommended PV array power [Wp]16000
Max. DC voltage [V]1000
Nominal DC operating voltage [V]600
Max. input current (input PV1 / input PV2 / input PV3) [A]PV1: 20 / PV2: 20 / PV3: 20
Start output voltage [V]140
No. of MPP trackers / Strings per MPP tracker3 / (1 / 1 / 1)
INPUT AC
Nominal AC power [VA]16000
Max. AC current [A]25.8
Rated grid frequency [Hz]50 / 60
Power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
OUTPUT AC (On-Grid)
Nominal AC power [VA]8000
Max. apparent AC power [VA]8800
Rated grid voltage(AC voltage range) [V]3P4W, 380 / 400
Rated grid frequency [Hz]50 / 60
Rated AC output current [A] ( at 230V, 50Hz)11.6
Max. AC current [A]12.8
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]< 3
EPS OUTPUT (With battery)
EPS peak power [VA]≤1.1Pn continuous operation;
1.1Pn-2Pn 10s;
>2Pn report error immediately
EPS rated power [VA]8000
EPS rated voltage [V]; frequency [Hz]3P4W, 380 / 400, 50 / 60
EPS rated current [A]11.6
Switchover time [ms]< 10
Total harmonic distortion (THDv, linear Load) [%]< 3
Half wave loads [kW]< 2
BATTERY
Battery voltage range [V]160 ~ 800
Communication interfacesCAN / RS485
BMS moduleTBMS-MCS0800E
Battery moduleTP-HS50E
CompositionTBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns)
Battery typeLi-ion (LFP)
Cycle life [Cycles]> 6000
Warranty [Years]10
SafetyCE, RCM, TUV (IEC62619), RoHS, REACH
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg]730 × 165 × 150 / 9.3
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg]730 × 318 × 150 / 47
Base dimensions(W × H × D) [mm] / Weight [kg]730 × 75 × 150 / 3.9
Series box dimensions(W × H × D) [mm] / Weight [kg]167 × 91.5 × 121 / 1.3
EFFICIENCY
Max. efficiency [%] / Euro-efficiency [%]98/ 97.7
Rated battery charge [%] / Discharge eciency [%]98.5 / 97
GENERAL DATA (INVERTER)
Dimensions (W × H × D) [mm]717 × 405 × 209.5
Weight [kg]40
Operating temperature range [°C]﹣35 to 60 (derating at +45)
Relative humidity [%]0 to 100 (condensing)
Storage temperature [°C]- 40 to 65
Noise emission (typical) [dB(A)]< 33
Internal consumption (night) [W]< 40 for hot standby, < 5 for cold standby
Idle modeYes
PROTECTION
Anti-Islanding protectionYes
DC reverse polarity protectionYes
Insulation monitoringYes
Residual current monitoringYes
AC overcurrent protectionYes
AC short-circuit protectionYes
AC overvoltage protectionYes
Over-heat protectionYes
AFCIOPT
Surge protectionType Ⅱ, DC and AC
STANDARD
SafetyIEC62109-1 / IEC62109-2
EMCEN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3
CertificationVDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21



X3-IES-10K-P
INPUT PV
Max. recommended PV array power [Wp]20000
Max. DC voltage [V]1000
Nominal DC operating voltage [V]600
Max. input current (input PV1 / input PV2 / input PV3) [A]PV1: 20 / PV2: 20 / PV3: 20
Start output voltage [V]140
No. of MPP trackers / Strings per MPP tracker3 / (1 / 1 / 1)
INPUT AC
Nominal AC power [VA]20000
Max. AC current [A]32
Rated grid frequency [Hz]50 / 60
Power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
OUTPUT AC (On-Grid)
Nominal AC power [VA]10000(AS4777 9999)
Max. apparent AC power [VA]10000(AS4777 9999)
Rated grid voltage(AC voltage range) [V]3P4W, 380 / 400
Rated grid frequency [Hz]50 / 60
Rated AC output current [A] ( at 230V, 50Hz)14.5
Max. AC current [A]14.5
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]< 3
EPS OUTPUT (With battery)
EPS peak power [VA]≤1.1Pn continuous operation;
1.1Pn-2Pn 10s;
>2Pn report error immediately
EPS rated power [VA]10000
EPS rated voltage [V]; frequency [Hz]3P4W, 380 / 400, 50 / 60
EPS rated current [A]14.5
Switchover time [ms]< 10
Total harmonic distortion (THDv, linear Load) [%]< 3
Half wave loads [kW]< 2
BATTERY
Battery voltage range [V]160 ~ 800
Communication interfacesCAN / RS485
BMS moduleTBMS-MCS0800E
Battery moduleTP-HS50E
CompositionTBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns)
Battery typeLi-ion (LFP)
Cycle life [Cycles]> 6000
Warranty [Years]10
SafetyCE, RCM, TUV (IEC62619), RoHS, REACH
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg]730 × 165 × 150 / 9.3
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg]730 × 318 × 150 / 47
Base dimensions(W × H × D) [mm] / Weight [kg]730 × 75 × 150 / 3.9
Series box dimensions(W × H × D) [mm] / Weight [kg]167 × 91.5 × 121 / 1.3
EFFICIENCY
Max. efficiency [%] / Euro-efficiency [%]98/ 97.7
Rated battery charge [%] / Discharge eciency [%]98.5 / 97
GENERAL DATA (INVERTER)
Dimensions (W × H × D) [mm]717 × 405 × 209.5
Weight [kg]40
Operating temperature range [°C]﹣35 to 60 (derating at +45)
Relative humidity [%]0 to 100 (condensing)
Storage temperature [°C]- 40 to 65
Noise emission (typical) [dB(A)]< 33
Internal consumption (night) [W]< 40 for hot standby, < 5 for cold standby
Idle modeYes
PROTECTION
Anti-Islanding protectionYes
DC reverse polarity protectionYes
Insulation monitoringYes
Residual current monitoringYes
AC overcurrent protectionYes
AC short-circuit protectionYes
AC overvoltage protectionYes
Over-heat protectionYes
AFCIOPT
Surge protectionType Ⅱ, DC and AC
STANDARD
SafetyIEC62109-1 / IEC62109-2
EMCEN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3
CertificationVDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21



X3-IES-12K-P
INPUT PV
Max. recommended PV array power [Wp]24000
Max. DC voltage [V]1000
Nominal DC operating voltage [V]600
Max. input current (input PV1 / input PV2 / input PV3) [A]PV1: 20 / PV2: 20 / PV3: 20
Start output voltage [V]140
No. of MPP trackers / Strings per MPP tracker3 / (1 / 1 / 1)
INPUT AC
Nominal AC power [VA]20000
Max. AC current [A]32
Rated grid frequency [Hz]50 / 60
Power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
OUTPUT AC (On-Grid)
Nominal AC power [VA]12000
Max. apparent AC power [VA]13200
Rated grid voltage(AC voltage range) [V]3P4W, 380 / 400
Rated grid frequency [Hz]50 / 60
Rated AC output current [A] ( at 230V, 50Hz)17.4
Max. AC current [A]19.2
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]< 3
EPS OUTPUT (With battery)
EPS peak power [VA]≤1.1Pn continuous operation;
1.1Pn-2Pn 10s;
>2Pn report error immediately
EPS rated power [VA]12000
EPS rated voltage [V]; frequency [Hz]3P4W, 380 / 400, 50 / 60
EPS rated current [A]17.4
Switchover time [ms]< 10
Total harmonic distortion (THDv, linear Load) [%]< 3
Half wave loads [kW]< 2
BATTERY
Battery voltage range [V]160 ~ 800
Communication interfacesCAN / RS485
BMS moduleTBMS-MCS0800E
Battery moduleTP-HS50E
CompositionTBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns)
Battery typeLi-ion (LFP)
Cycle life [Cycles]> 6000
Warranty [Years]10
SafetyCE, RCM, TUV (IEC62619), RoHS, REACH
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg]730 × 165 × 150 / 9.3
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg]730 × 318 × 150 / 47
Base dimensions(W × H × D) [mm] / Weight [kg]730 × 75 × 150 / 3.9
Series box dimensions(W × H × D) [mm] / Weight [kg]167 × 91.5 × 121 / 1.3
EFFICIENCY
Max. efficiency [%] / Euro-efficiency [%]98/ 97.7
Rated battery charge [%] / Discharge eciency [%]98.5 / 97
GENERAL DATA (INVERTER)
Dimensions (W × H × D) [mm]717 × 405 × 209.5
Weight [kg]40
Operating temperature range [°C]﹣35 to 60 (derating at +45)
Relative humidity [%]0 to 100 (condensing)
Storage temperature [°C]- 40 to 65
Noise emission (typical) [dB(A)]< 33
Internal consumption (night) [W]< 40 for hot standby, < 5 for cold standby
Idle modeYes
PROTECTION
Anti-Islanding protectionYes
DC reverse polarity protectionYes
Insulation monitoringYes
Residual current monitoringYes
AC overcurrent protectionYes
AC short-circuit protectionYes
AC overvoltage protectionYes
Over-heat protectionYes
AFCIOPT
Surge protectionType Ⅱ, DC and AC
STANDARD
SafetyIEC62109-1 / IEC62109-2
EMCEN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3
CertificationVDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21



X3-IES-15K-P
INPUT PV
Max. recommended PV array power [Wp]30000
Max. DC voltage [V]1000
Nominal DC operating voltage [V]600
Max. input current (input PV1 / input PV2 / input PV3) [A]PV1: 20 / PV2: 20 / PV3: 20
Start output voltage [V]140
No. of MPP trackers / Strings per MPP tracker3 / (1 / 1 / 1)
INPUT AC
Nominal AC power [VA]20000
Max. AC current [A]32
Rated grid frequency [Hz]50 / 60
Power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
OUTPUT AC (On-Grid)
Nominal AC power [VA]15000(AS4777 14999)
Max. apparent AC power [VA]165000
Rated grid voltage(AC voltage range) [V]3P4W, 380 / 400
Rated grid frequency [Hz]50 / 60
Rated AC output current [A] ( at 230V, 50Hz)21.8
Max. AC current [A]24
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]< 3
EPS OUTPUT (With battery)
EPS peak power [VA]≤1.1Pn continuous operation;
1.1Pn-2Pn 10s;
>2Pn report error immediately
EPS rated power [VA]15000
EPS rated voltage [V]; frequency [Hz]3P4W, 380 / 400, 50 / 60
EPS rated current [A]21.8
Switchover time [ms]< 10
Total harmonic distortion (THDv, linear Load) [%]< 3
Half wave loads [kW]< 2
BATTERY
Battery voltage range [V]160 ~ 800
Communication interfacesCAN / RS485
BMS moduleTBMS-MCS0800E
Battery moduleTP-HS50E
CompositionTBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns)
Battery typeLi-ion (LFP)
Cycle life [Cycles]> 6000
Warranty [Years]10
SafetyCE, RCM, TUV (IEC62619), RoHS, REACH
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg]730 × 165 × 150 / 9.3
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg]730 × 318 × 150 / 47
Base dimensions(W × H × D) [mm] / Weight [kg]730 × 75 × 150 / 3.9
Series box dimensions(W × H × D) [mm] / Weight [kg]167 × 91.5 × 121 / 1.3
EFFICIENCY
Max. efficiency [%] / Euro-efficiency [%]98/ 97.7
Rated battery charge [%] / Discharge eciency [%]98.5 / 97
GENERAL DATA (INVERTER)
Dimensions (W × H × D) [mm]717 × 405 × 209.5
Weight [kg]40
Operating temperature range [°C]﹣35 to 60 (derating at +45)
Relative humidity [%]0 to 100 (condensing)
Storage temperature [°C]- 40 to 65
Noise emission (typical) [dB(A)]< 33
Internal consumption (night) [W]< 40 for hot standby, < 5 for cold standby
Idle modeYes
PROTECTION
Anti-Islanding protectionYes
DC reverse polarity protectionYes
Insulation monitoringYes
Residual current monitoringYes
AC overcurrent protectionYes
AC short-circuit protectionYes
AC overvoltage protectionYes
Over-heat protectionYes
AFCIOPT
Surge protectionType Ⅱ, DC and AC
STANDARD
SafetyIEC62109-1 / IEC62109-2
EMCEN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3
CertificationVDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21


Related Products
Meter Meter
Meter
Smart Monitoring
DataHub 1000 DataHub 1000
DataHub 1000
Intelligent Export Control
Pocket Dongle Pocket Dongle
Pocket Dongle
SolaX Cloud Monitoring
Documents
Feedback
Info
Role
Installer
Distributor
End User
Others
Further information can be found in the privacy policy. I understand that I can withdraw my consent at any time.
I agree with SolaX data protection directive
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message