SolaX Power Network Technology (Zhejiang) Co.,Ltd.
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
ENGLISH(GLOBAL)
_1720421230
1
1
_1720407839
1
_1720407836
aelio design
Energy Storage System

ESS-AELIO

ESS-AELIO

Hybrid C&I ESS Cabinet  | P50B100 | P50B200 |  P60B100 | P60B200

High Performance


  • Max. 200% PV oversizing input

  • Up to 40A DC input current per MPPT

  • Global MPP scan for optimal energy harvest

  • Up to 200 kWh capacity with advanced LFP battery




Intelligent Design


  • AI-driven forecasting for solar and load management

  • Smart scene function for load management

  • VPP-ready with SolaX cloud support(2030.5,OpenADR)

  • Wireless meter solution & 24/7 scheduling


Assured Safety


  • Four-level fire safety protection & optional AFCI

  • IP66 rating for inverter, IP55 for cabinet

  • AC&DC SPD type ll, always guarding the inverter

  • Smart IV Curve scan for early panel diagnosis




Flexible Adaptability

  • Supports both on-grid and off-grid operation

  • Fast backup <10ms switchover time & 150% EPS output for 10s

  • Handles unbalanced loads across three phases

  • Expandable design with modular capacity options

Why ESS-AELIO

Aelio series is a highly integrated, all-in-one, C&I Hybrid energy storage cabinet with multiple application scenarios. It has outstanding advantages such as intelligent charge and discharge management, safety and reliability, and simple operation and maintenance. 


First of all, Aelio cabinet uses high-density, high-safety, and high-performance LFP batteries. There are two models with capacity of 100kWh and 200kWh. When used in a single cabinet or multiple cabinets, it can charge and discharge stably according to the set working modes at different time periods, and the large-capacity battery cell of 280Ah also reduces the intial cost of the system. 


Secondly, the cabinet is equipped with a self-developed Energy Management System (EMS) that can monitor the working status and abnormal alerts of each battery cell, PCS, and fire protection system in real-time. The local data storage capability allows for data analysis and verification for up to 1 year. The advanced EMS system also has leading advantages in intelligent control of different smart operation strategies, autonomous scheduling based on local electricity prices, and comprehensive management of photovoltaic, energy storage systems, EV charging and generators at power plant level. These features improve the overall system efficiency and shorten the investment return period. 


In addition, the cabinet also has multiple safety protection measures. It has built-in protection functions such as overvoltage, overcurrent, and overtemperature. It is also equipped with fireproof materials and 4 levels of fire protection system, which can promptly detect and respond to potential fire risks, effectively control the spread of fires and reduce the risk of safety accidents. 


The cabinet is suitable for various C&I PV&ESS scenarios, including peak shaving, demand response, backup mode, photovoltaic and energy storage integration, and stable load consumption curves. It also supports applications such as virtual power plants(VPP) and frequency regulation





AELIO-P50B100
AELIO-P50B200
AELIO-P60B100
AELIO-P60B200
AttributeAELIO-P50B100
Rated AC output power [kW]50
Rated AC output current [A]72.2
Max. AC output apparent power   [kVA]55
Max. AC output current [A]83.6
Nominal grid voltage [V]3P4W, 400/230, 380/220
Nominal grid frequency [Hz]50/60
Adjustable power factor range1 (0.8 Leading ~ 0.8 Lagging)
THDi (Rated power) [%]< 3
Battery typeLFP / 280Ah
Rated battery capacity [kWh]100
Rated battery voltage [V]358.4
Battery voltage range [V]280 ~ 408.8
Discharge depth [%]90
Rated charge/discharge current   [A]140
Max charge/discharge current   [A]160 (80 × 2)
Max. PV input power [kW]100
Max. PV input voltage [V]1000
Start output voltage [V]200
Rated input voltage [V]650
MPPT voltage range [V]160 ~ 950
No. of MPP trackers / Strings   per MPP tracker5 (2 per MPPT)
Max. input current [A]40
Max. input short circuit   current [A]50
Dimensions(with Inverter)   (W×H×D) [mm]1310 × 2300 × 1140
Dimensions (without Inverter)   (W×H×D) [mm]1020 × 2300 × 1150
Weight (with Inverter) [kg]1600
Weight (without Inverter) [kg]1500
Operating ambient temperature   range [°C]-30 ~ 55
Relative humidity   (Non-condensing) [%]0 ~ 95
Max. operating altitude [m]3000
Cooling conceptSmart air cooling
Ingress protectionCabinet: IP55; Inverter: IP66
Fire protectionAerosol(Optional:Novec1230 ) / Water
TopologyNon-isolated
StandardIIEC62619, IEC63056:2000, IEC61000, IEC62477-1, UN38.3


AttributeAELIO-P50B200
Rated AC output power [kW]50
Rated AC output current [A]72.2
Max. AC output apparent power   [kVA]55
Max. AC output current [A]83.6
Nominal grid voltage [V]3P4W, 400/230, 380/220
Nominal grid frequency [Hz]50/60
Adjustable power factor range1 (0.8 Leading ~ 0.8 Lagging)
THDi (Rated power) [%]< 3
Battery typeLFP / 280Ah
Rated battery capacity [kWh]200
Rated battery voltage [V]716.8
Battery voltage range [V]560 ~ 817.6
Discharge depth [%]90
Rated charge/discharge current   [A]140
Max charge/discharge current   [A]160 (80 × 2)
Max. PV input power [kW]100
Max. PV input voltage [V]1000
Start output voltage [V]200
Rated input voltage [V]650
MPPT voltage range [V]160 ~ 950
No. of MPP trackers / Strings   per MPP tracker5 (2 per MPPT)
Max. input current [A]40
Max. input short circuit   current [A]50
Dimensions(with Inverter)   (W×H×D) [mm]2070 × 2420 × 1200
Dimensions (without Inverter)   (W×H×D) [mm]1680 × 2420 × 1200
Weight (with Inverter) [kg]2800
Weight (without Inverter) [kg]2700
Operating ambient temperature   range [°C]-30 ~ 55
Relative humidity   (Non-condensing) [%]0 ~ 95
Max. operating altitude [m]3000
Cooling conceptSmart air cooling
Ingress protectionCabinet: IP55; Inverter: IP66
Fire protectionAerosol(Optional:Novec1230 ) / Water
TopologyNon-isolated
StandardIIEC62619, IEC63056:2000, IEC61000, IEC62477-1, UN38.3


AttributeAELIO-P60B100
Rated AC output power [kW]60
Rated AC output current [A]86.6
Max. AC output apparent power   [kVA]66
Max. AC output current [A]100.3
Nominal grid voltage [V]3P4W, 400/230, 380/220
Nominal grid frequency [Hz]50/60
Adjustable power factor range1 (0.8 Leading ~ 0.8 Lagging)
THDi (Rated power) [%]< 3
Battery typeLFP / 280Ah
Rated battery capacity [kWh]100
Rated battery voltage [V]358.4
Battery voltage range [V]280 ~ 408.8
Discharge depth [%]90
Rated charge/discharge current   [A]140
Max charge/discharge current   [A]160 (80 × 2)
Max. PV input power [kW]120
Max. PV input voltage [V]1000
Start output voltage [V]200
Rated input voltage [V]650
MPPT voltage range [V]160 ~ 950
No. of MPP trackers / Strings   per MPP tracker6 (2 per MPPT)
Max. input current [A]40
Max. input short circuit   current [A]50
Dimensions(with Inverter)   (W×H×D) [mm]1310 × 2300 × 1140
Dimensions (without Inverter)   (W×H×D) [mm]1020 × 2300 × 1150
Weight (with Inverter) [kg]1600
Weight (without Inverter) [kg]1500
Operating ambient temperature   range [°C]-30 ~ 55
Relative humidity   (Non-condensing) [%]0 ~ 95
Max. operating altitude [m]3000
Cooling conceptSmart air cooling
Ingress protectionCabinet: IP55; Inverter: IP66
Fire protectionAerosol(Optional:Novec1230 ) / Water
TopologyNon-isolated
StandardIIEC62619, IEC63056:2000, IEC61000, IEC62477-1, UN38.3


AttributeAELIO-P60B200
Rated AC output power [kW]60
Rated AC output current [A]86.6
Max. AC output apparent power   [kVA]66
Max. AC output current [A]100.3
Nominal grid voltage [V]3P4W, 400/230, 380/220
Nominal grid frequency [Hz]50/60
Adjustable power factor range1 (0.8 Leading ~ 0.8 Lagging)
THDi (Rated power) [%]< 3
Battery typeLFP / 280Ah
Rated battery capacity [kWh]200
Rated battery voltage [V]716.8
Battery voltage range [V]560 ~ 817.6
Discharge depth [%]90
Rated charge/discharge current   [A]140
Max charge/discharge current   [A]160 (80 × 2)
Max. PV input power [kW]120
Max. PV input voltage [V]1000
Start output voltage [V]200
Rated input voltage [V]650
MPPT voltage range [V]160 ~ 950
No. of MPP trackers / Strings   per MPP tracker6 (2 per MPPT)
Max. input current [A]40
Max. input short circuit   current [A]50
Dimensions(with Inverter)   (W×H×D) [mm]2070 × 2420 × 1200
Dimensions (without Inverter)   (W×H×D) [mm]1680 × 2420 × 1200
Weight (with Inverter) [kg]2800
Weight (without Inverter) [kg]2700
Operating ambient temperature   range [°C]-30 ~ 55
Relative humidity   (Non-condensing) [%]0 ~ 95
Max. operating altitude [m]3000
Cooling conceptSmart air cooling
Ingress protectionCabinet: IP55; Inverter: IP66
Fire protectionAerosol(Optional:Novec1230 ) / Water
TopologyNon-isolated
StandardIIEC62619, IEC63056:2000, IEC61000, IEC62477-1, UN38.3


Related Products
Meter Meter
Meter
Smart Monitoring
DataHub 1000 DataHub 1000
DataHub 1000
Intelligent Export Control
Pocket Dongle Pocket Dongle
Pocket Dongle
SolaX Cloud Monitoring
Documents
Datasheet
Language
English
Format
PDF
Size
559KB
Last updated
18/10/2024
Language
Deutsch
Format
PDF
Size
304k
Last updated
09/08/2024
User Manual
Language
English
Format
PDF
Size
96.3M
Last updated
08/07/2024
Language
Nederlands
Format
PDF
Size
77.5MB
Last updated
20/09/2024
Quick Installation Guide
Language
English
Format
PDF
Size
66.4M
Last updated
08/07/2024
Maintenance Guide
Language
English
Format
PDF
Size
70.4M
Last updated
26/09/2024
Language
Chinese
Format
PDF
Size
70.4M
Last updated
30/09/2024
Feedback
Info
Role
Installer
Distributor
End User
Others
Further information can be found in the privacy policy. I understand that I can withdraw my consent at any time.
I agree with SolaX data protection directive
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message