75kW / 80kW / 100kW / 110kW
120kW / 125kW / 136kW / 150kW
Flexible Adaptability
Built-in export power control function
Remote setting and upgrading
Aluminium AC cable connection available
High Efficiency
Up to 99% efficiency
32A per MPP tracker
180~1000Vdc MPPT voltage range
150% PV oversizing, 110% overloading output
Max. 12 MPPTs, 2 strings per MPP tracker
Intelligent Design
Night-time reactive power compensation
Smart air cooling enhances fan longevity
Heat dissipation reduces system weight & size by over 5%
I-V curve diagnosis
Assured Safety
IP66 protection degree
AFCI support (optional)
AC terminal temperature detection
String current monitoring
24 hours operation monitoring
Type II SPD on AC&DC side
Specifications | X3-FTH-75K On-grid Inverter |
Max. recommended PV array power | 120 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 580 V / 600 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 9 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 75 kW |
Rated output current | 113.7 A / 108.7 A |
Max. output apparent power | 75 kVA |
Max. output continuous current | 113.7 A / 108.7 A |
Nominal AC voltage | 3 / (N) / PE, 220 / 380 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |
Specifications | X3-FTH-80K On-grid Inverter |
Max. recommended PV array power | 120 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 580 V / 600 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 9 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 80 kW |
Rated output current | 121.3 A / 116 A |
Max. output apparent power | 88 kVA |
Max. output continuous current | 133.4 A / 127.6 A |
Nominal AC voltage | 3 / (N) / PE, 220 / 380 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |
Specifications | X3-FTH-100K On-grid Inverter |
Max. recommended PV array power | 150 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 580 V / 600 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 9 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 100 kW |
Rated output current | 151.6 A / 145 A |
Max. output apparent power | 110 kVA |
Max. output continuous current | 166.7 A / 159.5 A |
Nominal AC voltage | 3 / (N) / PE, 220 / 380 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |
Specifications | X3-FTH-110K On-grid Inverter |
Max. recommended PV array power | 165 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 580 V / 600 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 9 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 110 kW |
Rated output current | 166.7 A / 159.5 A |
Max. output apparent power | 121 kVA |
Max. output continuous current | 183.4 A / 175.4 A |
Nominal AC voltage | 3 / (N) / PE, 220 / 380 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |
Specifications | X3-FTH-120K On-grid Inverter |
Max. recommended PV array power | 180 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 580 V / 600 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 12 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 120 kW |
Rated output current | 181.9 A / 174 A |
Max. output apparent power | 132 kVA |
Max. output continuous current | 200 A / 191.3 A |
Nominal AC voltage | 3 / (N) / PE, 220 / 380 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |
Specifications | X3-FTH-136K-MV On-grid Inverter |
Max. recommended PV array power | 204 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 730 V / 785 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 12 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 136 kW |
Rated output current | 157.1 A / 145.4 A |
Max. output apparent power | 149.6 kVA |
Max. output continuous current | 172.8 A / 160 A |
Nominal AC voltage | 3 / PE, 500 / 540 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |
Specifications | X3-FTH-150K-MV On-grid Inverter |
Max. recommended PV array power | 225 kWp |
Max. PV input voltage | 1100 V |
Nominal PV input voltage | 730 V / 785 V |
Operating voltage range | 200 ~ 1000 V |
MPPT voltage range | 180 ~ 1000 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 12 / 2 |
Max. input current per MPPT | 32 A |
Max. input short circuit current per MPPT | 46 A |
Rated output power | 150 kW |
Rated output current | 173.2 A / 160.4 A |
Max. output apparent power | 165 kVA |
Max. output continuous current | 190.6 A / 176.5 A |
Nominal AC voltage | 3 / PE, 500 / 540 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | < 3% |