3.8kW / 5kW / 6kW / 7.6kW
200% PV oversize, 15.2kWdc
3 strings MPPT
150% Max. MPPT power
16A Max. input current
100% backup power with grid-tie
Built-in RGM meter
Up to 4 inverter parallel
Peak efficiency(PV-GRID): 98%
Specifications | A1-Hybrid-3.8-G2 |
Max. recommended PV power [W] | 7600 |
Max. MPPT power [W] | 5700 |
Max. DC voltage [V] | 550 |
Max. input current [A] | A: 20 / B: 20 |
Start input voltage [V] | 120 |
No. of MPP trackers | 2 |
Strings per MPP tracker | A: 1 / B: 1 |
DC disconnection switch | YES |
AFCI | YES |
Nominal AC power [VA] | 3816 |
Max. apparent AC power [VA] | 3816 |
Rated grid voltage (AC voltage range) [V] | 240 |
Rated grid Frequency [Hz] | 60 |
Nominal AC current [A] | 15.9 |
Max. AC current [A] | 15.9 |
Maximum output fault current and duration [A/ms] | 17.5 / 20 |
Displacement power factor | 0.8 leading to 0.8 lagging |
Total harmonic distortion (THD, rated power) | < 3% |
Parallel operation | YES |
Dimensions with safety switch (WxHxD) [in (mm)] | 33.1 in x 15.7 in x 5.7 in (840 mm x 400 mm x 145 mm) |
Weight with safety switch [lb (kg)] | 75 lbs (34 kg) |
Warranty | 10 years |
Specifications | A1-Hybrid-5.0-G2 |
Max. recommended PV power [W] | 10000 |
Max. MPPT power [W] | 7500 |
Max. DC voltage [V] | 550 |
Max. input current [A] | A: 20 / B: 20 |
Start input voltage [V] | 120 |
No. of MPP trackers | 2 |
Strings per MPP tracker | A: 1 / B: 1 |
DC disconnection switch | YES |
AFCI | YES |
Nominal AC power [VA] | 5016 |
Max. apparent AC power [VA] | 5016 |
Rated grid voltage (AC voltage range) [V] | 240 |
Rated grid Frequency [Hz] | 60 |
Nominal AC current [A] | 20.9 |
Max. AC current [A] | 20.9 |
Maximum output fault current and duration [A/ms] | 23 / 20 |
Displacement power factor | 0.8 leading to 0.8 lagging |
Total harmonic distortion (THD, rated power) | < 3% |
Parallel operation | YES |
Dimensions with safety switch (WxHxD) [in (mm)] | 33.1 in x 15.7 in x 5.7 in (840 mm x 400 mm x 145 mm) |
Weight with safety switch [lb (kg)] | 75 lbs (34 kg) |
Warranty | 10 years |
Specifications | A1-Hybrid-6.0-G2 |
Max. recommended PV power [W] | 10000 |
Max. MPPT power [W] | 9000 |
Max. DC voltage [V] | 550 |
Max. input current [A] | A: 16 / B: 16 |
Start input voltage [V] | 120 |
No. of MPP trackers | 2 |
Strings per MPP tracker | A: 1 / B: 1 |
DC disconnection switch | YES |
AFCI | YES |
Nominal AC power [VA] | 6000 |
Max. apparent AC power [VA] | 6000 |
Rated grid voltage (AC voltage range) [V] | 240 |
Rated grid Frequency [Hz] | 60 |
Nominal AC current [A] | 25 |
Max. AC current [A] | 25 |
Maximum output fault current and duration [A/ms] | 27.5 / 20 |
Displacement power factor | 0.8 leading to 0.8 lagging |
Total harmonic distortion (THD, rated power) | < 3% |
Parallel operation | YES |
Dimensions with safety switch (WxHxD) [in (mm)] | 33.1 in x 15.7 in x 5.7 in (840 mm x 400 mm x 145 mm) |
Weight with safety switch [lb (kg)] | 75 lbs (34 kg) |
Warranty | 10 years |
Specifications | A1-Hybrid-7.6-G2 |
Max. recommended PV power [W] | 15200 |
Max. MPPT power [W] | 11400 |
Max. DC voltage [V] | 550 |
Max. input current [A] | A: 20 / B: 20 / C: 20 |
Start input voltage [V] | 120 |
No. of MPP trackers | 3 |
Strings per MPP tracker | A: 1 / B: 1 / C: 1 |
DC disconnection switch | YES |
AFCI | YES |
Nominal AC power [VA] | 7608 |
Max. apparent AC power [VA] | 7608 |
Rated grid voltage (AC voltage range) [V] | 240 |
Rated grid Frequency [Hz] | 60 |
Nominal AC current [A] | 31.7 |
Max. AC current [A] | 31.7 |
Maximum output fault current and duration [A/ms] | 34.9 / 20 |
Displacement power factor | 0.8 leading to 0.8 lagging |
Total harmonic distortion (THD, rated power) | < 3% |
Parallel operation | YES |
Dimensions with safety switch (WxHxD) [in (mm)] | 33.1 in x 15.7 in x 5.7 in (840 mm x 400 mm x 145 mm) |
Weight with safety switch [lb (kg)] | 75 lbs (34 kg) |
Warranty | 10 years |