0.6kW / 0.7kW / 1.1kW / 1.5kW
2kW / 2.5kW / 3kW / 3.3kW / 3.6kW
0.6kW / 0.7kW / 0.8kW / 1.1kW
1.5kW / 2kW / 2.5kW / 3kW / 3.3kW
Small and compact size
Remote upgrade and maintenance
150% oversizing and 110% overloading
Max. DC input 14A per string
Low start-up voltage and wide MPPT range
SPD on both AC and DC side integrated
Max. PV input voltage | 450V |
Max. PV input current | 14A |
No. of MPP trackers/Strings per MPP tracker | 1/1 |
Operating ambient temperature range | -25~+60°C |
Dimensions (W*H*D) | 267*328*126mm |
Net weight | 6kg |
Max. PV input voltage | 550V |
Max. PV input current | 14A |
No. of MPP trackers/Strings per MPP tracker | 1/1 |
Operating ambient temperature range | -25~+60°C |
Dimensions (W*H*D) | 267*328*126mm |
Net weight | 8.3kg |
10s data refresh on SolaX Cloud
I-V curve diagnosis
Supports parallel operation for up to 5 inverters, no external EMS required
Smart loads management (e.g., heat pump, smart EV charger)
200% PV oversizing and 16A input to support
High-power panels
Ultra-Wide MPPT voltage range
Global MPP tracking with shade optimization
Type II SPD on AC&DC side
Ready for Rapid Shutdown function
AFCI support (optional)
Built-in export control function
Parameter | X1-MINI-0.6K-G4 |
Max. recommended PV array power | 1.2 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 600 |
Rated output current | 2.6 |
Max. output apparent power | 600 |
Max. output continuous current | 3 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-0.7K-G4 |
Max. recommended PV array power | 1.4 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 700 |
Rated output current | 3.1 |
Max. output apparent power | 770 |
Max. output continuous current | 3.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-0.8K-G4 |
Max. recommended PV array power | 1.6 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 800 |
Rated output current | 3.5 |
Max. output apparent power | 800 |
Max. output continuous current | 3.7 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-1.1K-G4 |
Max. recommended PV array power | 2.2 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 1100 |
Rated output current | 4.8 |
Max. output apparent power | 1210 |
Max. output continuous current | 5.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-1.5K-G4 |
Max. recommended PV array power | 3 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 1500 |
Rated output current | 6.5 |
Max. output apparent power | 1650 |
Max. output continuous current | 7.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-2.0K-G4 |
Max. recommended PV array power | 4 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 2000 |
Rated output current | 8.7 |
Max. output apparent power | 2200 |
Max. output continuous current | 10 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-2.5K-G4 |
Max. recommended PV array power | 5 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 2500 |
Rated output current | 10.9 |
Max. output apparent power | 2750 |
Max. output continuous current | 12.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-3.0K-G4 |
Max. recommended PV array power | 6 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 3000 |
Rated output current | 13.1 |
Max. output apparent power | 3300 |
Max. output continuous current | 15 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-3.3K-G4 |
Max. recommended PV array power | 6.6 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 3300 |
Rated output current | 14.4 |
Max. output apparent power | 3300 |
Max. output continuous current | 15 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |