Rapid Shutdown Device | 1 connection
Rapid Shutdown Device | 2 connection
TRANSMITTER KIT
Max. 20A PV input current
Lower power consumption & wider operating voltage
Faster installation with plug-and-play cables and connectors
Ultra-low signal noise, enhancing system stability
Module-level rapid shutdown
IP68 with unrivaled reliability
Compatible with all SolaX inverters and other major inverter brands
Compatible with mainstream PV panels
Type | Details |
Product | XRSD-1C |
ELECTRICAL DATA | |
Input voltage range [V] | 8-80 |
Output voltage range [V] | 8-80 |
Max. PV input current [A] | 20 |
Max. short circuit current [A] | 26 |
Recommended fuse rating [A] | 30 |
Maximum system voltage [V] | 1500 |
MECHANICAL | |
Dimensions* (W x H x D) [mm] | 130 × 36 × 21 |
Weight [g] | 400 |
Input connectors | MC4 (Standard) |
Input cable length [m] | 0.2 |
Output connectors | MC4 (Standard) |
Output cable length [m] | 1.2 |
Communication type | PLC |
ENVIRONMENT LIMIT | |
Protection class | IP68 / NEMA6P |
Operating temperature range [°C] | -40°C to +85°C (-40°F to +185°F) |
COMPLIANCE | |
Safety | EN 62109-1:2010 |
EMC | EN IEC 61000-6-1 / 2 / 3 / 4; EN IEC 61000-3-2 / 3 / 11 / 12; EN 55011 |
Max. 20A PV input current
Lower power consumption & wider operating voltage
Faster installation with plug-and-play cables and connectors
Ultra-low signal noise, enhancing system stability
Module-level rapid shutdown
IP68 with unrivaled reliability
Compatible with all SolaX inverters and other major inverter brands*
Compatible with mainstream PV panels
Type | Details |
Product | XRSD-2C |
ELECTRICAL DATA | |
Input voltage range [V] | 8 ~ 80 V |
Output voltage range [V] | 16-160 |
Max. PV input current [A] | 20 |
Max. short circuit current [A] | 26 |
Recommended fuse rating [A] | 30 |
Maximum system voltage [V] | 1500 |
MECHANICAL | |
Dimensions* (W x H x D) [mm] | 135 × 59 × 20 mm |
Weight [g] | 720 |
Input connectors | MC4 (Standard) |
Input cable length [m] | 0.45 |
Output connectors | MC4 (Standard) |
Output cable length [m] | 2.4 |
Communication type | PLC |
ENVIRONMENT LIMIT | |
Protection class | IP68 / NEMA6P |
Operating temperature range [°C] | -40°C to +85°C (-40°F to +185°F) |
COMPLIANCE | |
Safety | EN 62109-1:2010 |
EMC | EN IEC 61000-6-1 / 2 / 3 / 4; EN IEC 61000-3-2 / 3 / 11 / 12; EN 55011 |
IP65 protection degree
Seamlessly compatible with SolaX XRSD receivers for module-level rapid shutdown
Supports up to 2 cores per transmitter
Type | Details |
Product | XRSD-CORE KIT |
ELECTRICAL DATA | |
Power supply input voltage [Vac] | 85-264 |
Transmitter input voltage [Vdc] | 12 (+/-2%) |
Transmitter input current [A] | 1 |
CORE | |
Max. Number of core | 2 |
Max. Current per core [A] | 150A |
Max. String voltage [Vdc] | 1500 |
Diameter [mm] | ~31 (Inner) / 65 (Outer) |
Max. Number of strings per core | 10 (This data refers to a cable diameter of Φ 6 mm) |
MECHANICAL | |
Dimensions (W x H x D) [mm] | 200 x 300 x 170 |
ENVIRONMENT LIMIT | |
Protection class | IP65 / NEMA4 |
Operating temperature range [°C] | -40°C to +75°C (-40°F to +175°F) |
COMPLIANCE | |
Safety | EN 62109-1:2010 |