15kW / 19.9kW
20kW / 25kW / 30kW
Single unit UPS-level switchover time<10ms
Built-in shadow tracking
Smart loads management(e.g., heat pump, smart EV charger)
Loads respond time within 0.3 s
VPP ready with a variety of compatibility
(OpenADR, IEEE2030.5, FCAS, API)*
Max. 10pcs parallel for on-grid and off-grid
Microgrid and generator function for versatile operations
Max. 36A PV input per MPPT, optimized for high-power solar panel
Battery terminal temperature detection
IP66 protection degree
Type II SPD on AC&DC side
Optional AFCI protection
200% PV oversizing and up to 110% AC output
200% EPS overload for 10s
Max. 60A charging / discharging current
Low start-up voltage for longer operation
Parameter | X3-ULT-15K |
Max. recommended PV array power | 30 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 2 / (2 / 2) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A |
Rated output power | 15000 W (AS4777 14999 W) |
Rated output current | 21.8 A |
Max. output apparent power | 16500 VA (AS4777 14999 VA) |
Max. output continuous current | 24.0 A (AS4777 21.8 A) |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 15000 VA |
Max. AC input current | 21.8 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |
Parameter | X3-ULT-15KP |
Max. recommended PV array power | 30 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 3 / (2 / 2 / 2) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A |
Rated output power | 15000 W (AS4777 14999 W) |
Rated output current | 21.8 A |
Max. output apparent power | 16500 VA (AS4777 14999 VA) |
Max. output continuous current | 24.0 A (AS4777 21.8 A) |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 15000 VA |
Max. AC input current | 21.8 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |
Parameter | X3-ULT-19.9K |
Max. recommended PV array power | 40 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 2/ (2 / 2 ) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A / 45 A |
Rated output power | 19999 W |
Rated output current | 29.0 A |
Max. output apparent power | 19999 VA |
Max. output continuous current | 29.0 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 19999 VA |
Max. AC input current | 29.0 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |
Parameter | X3-ULT-20K |
Max. recommended PV array power | 40 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 2 / (2 / 2) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A |
Rated output power | 20000 W |
Rated output current | 29.0 A |
Max. output apparent power | 22000 VA |
Max. output continuous current | 31.9 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 20000 VA |
Max. AC input current | 29.0 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |
Parameter | X3-ULT-20KP |
Max. recommended PV array power | 40 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 3/ (2 / 2 / 2) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A |
Rated output power | 20000 W |
Rated output current | 29.0 A |
Max. output apparent power | 22000 VA |
Max. output continuous current | 31.9 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 20000 VA |
Max. AC input current | 29.0 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |
Parameter | X3-ULT-25K |
Max. recommended PV array power | 50 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 3 / (2 / 2 / 2) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A / 45 A |
Rated output power | 25000 W (VDE 4105 24900 W) |
Rated output current | 36.3 A |
Max. output apparent power | 27500 VA (VDE 4105 24900 VA) |
Max. output continuous current | 39.9 A (VDE 4105 36.3 A) |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 25000 VA |
Max. AC input current | 36.3 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |
Parameter | X3-ULT-30K |
Max. recommended PV array power | 60 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 600 V |
Operating voltage range | 120 ~ 950 V |
MPPT voltage range | 160 ~ 950 V |
Start-up voltage | 200 V |
No. of MPP trackers / Strings per MPP tracker | 3 / (2 / 2 / 2) |
Max. input current per MPPT (MPPT1/2/3) | 36 A / 36 A / 36 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 45 A / 45 A / 45 A |
Rated output power | 30000 W (AS4777 29999 W, VDE 4105 29900 W) |
Rated output current | 43.5 A |
Max. output apparent power | 30000 VA (AS4777 29999 VA, VDE 4105 29900 VA) |
Max. output continuous current | 43.5 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 30000 VA |
Max. AC input current | 43.5 A |
Nominal AC frequency | 50 Hz / 60 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Battery type | Lithium |
Battery voltage range | 120 ~ 800 V |