3kW / 3.3kW / 3.6kW / 4.2kW
4.6kW / 5kW / 5.5kW / 6kW
2.5kW / 3kW / 3.3kW / 3.6kW
4kW / 4.2kW / 5kW / 6kW
Superior Performance
150% oversizing and 110% overloading
DC input 14A per string
User-Friendly
24H monitoring and maintenance (Optional)
Easy to install and set up
Assured Safety Reliability
AC/DC built-in Type III SPD (Optional)
Over-temperature protection
Export control function integrated
Max. PV input voltage | 600V |
Max. PV input current (PV1/PV2) | 14A/14A |
No. of MPP trackers/Strings per MPP tracker | 2/1 |
Operating ambient temperature range | -25~+60°C |
Dimensions (W*H*D) | 341.5*430*143mm |
Net weight | 13.5kg |
Max. PV input voltage | 600V |
Max. PV input current (PV1/PV2) | 14A/14A |
No. of MPP trackers/Strings per MPP tracker | 2/1 |
Operating ambient temperature range | -25~+60°C |
Dimensions (W*H*D) | 341.5*430*143mm |
Net weight | 15kg |
Flexible Adaptability
Supports parallel operation for up to 5 inverters, no external EMS required
Smart loads management (e.g., heat pump, smart EV charger)
High Efficiency
200% PV oversizing and 16A input to support high-power panels
50V startup voltage
Built-in export control
Assured Safety
Type II SPD on AC&DC side
Ready for Rapid Shutdown function
AFCI support (optional)
Built-in export control function
Intelligent Design
10s data refresh on SolaX Cloud
Easy configuration via WiFi & App
I-V Curve diagnosis
Model | X1-BOOST-2.5K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 6 |
Rated output power (W) | 2500 |
Rated output current (A) | 10.9 |
Max. output apparent power (VA) | 2750 |
Max. output continuous current (A) | 12 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-3K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 6 |
Rated output power (W) | 3000 |
Rated output current (A) | 13.1 |
Max. output apparent power (VA) | 3300 |
Max. output continuous current (A) | 14.4 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-3.3K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 6.6 |
Rated output power (W) | 3300 |
Rated output current (A) | 14.4 |
Max. output apparent power (VA) | 3630 |
Max. output continuous current (A) | 15.8 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-3.6K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 7.2 |
Rated output power (W) | 3680 |
Rated output current (A) | 16 |
Max. output apparent power (VA) | 4048 |
Max. output continuous current (A) | 17.6 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-4K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 8 |
Rated output power (W) | 4000 |
Rated output current (A) | 17.4 |
Max. output apparent power (VA) | 4000 |
Max. output continuous current (A) | 17.4 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-4.2K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 8 |
Rated output power (W) | 4200 |
Rated output current (A) | 18.3 |
Max. output apparent power (VA) | 4620 |
Max. output continuous current (A) | 20.1 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-5K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 10 |
Rated output power (W) | 5000 |
Rated output current (A) | 21.7 |
Max. output apparent power (VA) | 5000 |
Max. output continuous current (A) | 21.7 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |
Model | X1-BOOST-6K-G4 |
Max. PV input voltage | 600 V |
Nominal PV input voltage | 360 V |
Operating voltage range | 35 ~ 600 V |
MPPT voltage range | 40 ~ 560 V |
Start-up voltage | 50 V |
No.ofMPPtrackers /Strings per MPPtracker | 2 / (1 / 1) |
Max. input current per MPPT(MPPT1/2) | 16 A / 16 A |
Max. input short circuit current per MPPT(MPPT1/2) | 22 A / 22 A |
Max. recommended PV array power (kWp) | 12 |
Rated output power (W) | 6000 |
Rated output current (A) | 26.1 |
Max. output apparent power (VA) | 6000 |
Max. output continuous current (A) | 27.3 |
Nominal AC voltage | 1/N/PE, 220/230/240 V |
Nominal AC frequency (Hz) | 50 / 60 |